Gas appliances in bedrooms and bathrooms: the rules

In a bathroom or shower room any gas appliance must be room-sealed. In a bedroom a gas fire, space heater or water heater over 14 kW gross must be room-sealed; at 14 kW or less it must be room-sealed or shut itself down before fumes build up. A cupboard off, or venting into, either room counts as the room.

Reviewed by Jordan Valentine-Dunn, Gas Safe registered engineer · Portsmouth Gas Heating · Last reviewed October 2026

The rule is regulation 30 of the Gas Safety (Installation and Use) Regulations 1998. A modern room-sealed combi meets it in either room, so a boiler in a bedroom cupboard is allowed. In a bathroom the boiler maker's electrical rules then decide where on the wall it can go.

What does regulation 30 say about bedrooms and bathrooms?

It restricts which appliances may be installed in three places: bathrooms and shower rooms, rooms used for sleeping, and anywhere at all for an instantaneous water heater. Room-sealed means the appliance takes its air from outside and discharges its flue gases outside, so nothing it burns mixes with the room's air.

Regulation 30 of the Gas Safety (Installation and Use) Regulations 1998, as read on legislation.gov.uk in October 2026
RoomApplianceMay be installed only ifRegulation
Bathroom or shower roomAny gas applianceIt is room-sealed30(1)
Room used or intended for sleepingGas fire, other space heater or water heater of more than 14 kW gross heat inputIt is room-sealed30(2)
Room used or intended for sleepingGas fire, other space heater or water heater of 14 kW gross heat input or lessIt is room-sealed, or has a safety control that shuts it down before a dangerous quantity of combustion products builds up30(3)
Any roomInstantaneous water heaterIt is room-sealed, or has that safety control30(3)
Cupboard or compartment within one of those rooms, or next to it with an air vent into itAs for the roomThe same rule as the room it opens or vents into30(4)

HSE's approved code of practice, L56, words the bedroom line differently. Its paragraph 263 says appliances of 14 kW or more should not go in a bedroom unless room-sealed, and those of less than 14 kW may with the safety control. The regulation says more than 14 kW and 14 kW or less, and the regulation is the law.

Can you have a gas boiler in a bedroom?

Yes, if it is room-sealed, which a modern fanned-flue boiler is. L56 counts central heating appliances among those regulation 30 covers. Worcester rates the Greenstar 4000 combi and Ideal the Logic Combi2 as types C13, C33 and C53, the room-sealed types, so either may go in a bedroom or a cupboard opening off one. An open-flued boiler over 14 kW may not.

Can you have a gas fire in a bedroom?

Only a room-sealed one above 14 kW gross. At 14 kW or less an open-flued fire may go in a bedroom if it has a device that turns the gas off before a dangerous level of fumes builds up, as L56 puts it. On a service the engineer checks that device as one of the fire's safety controls.

Can a gas boiler go in a bathroom?

Yes, if it is room-sealed, and then the boiler's electrical rating and the zones in BS 7671, the IET Wiring Regulations, decide where. The two manuals differ: Ideal's Logic Combi2 must sit beyond Zone 2, while Worcester rates the Greenstar 4000 IPX4D and asks only that mains switches and controls are out of reach of the bath or shower.

What two makers' installation manuals say about a room containing a bath or shower, read in October 2026
BoilerRating the maker printsWhere it may goZone figures in the manual's drawing
Ideal Logic Combi2 (UIN 237664 A08, section 1.7)IP20; do not clean with jets of waterBeyond Zone 2, as detailed in BS 7671600 mm radius from the bath or shower; zone 2 extends 600 mm from the bath without an end wall; 2250 mm high
Worcester Bosch Greenstar 4000 combi (6720891161, section 4.3.2)IPX4D, kept with a Key controlTo BS 7671; mains switches and controls out of reach of a person using the bath or showerThe same figures, marked for guidance only

Does a cupboard off a bedroom count as the bedroom?

Yes, when it opens off the room or ventilates through it. Regulation 30(4) covers a cupboard or compartment within the room, and one next to it with an air vent into it. L56 paragraph 264 adds the reverse: a space whose ventilation comes from somewhere else, with no vent into the bedroom or bathroom, is outside the rule.

What if a room becomes a bedroom later?

The rule follows the room's use. L56 paragraph 265 counts rooms intended as bedrooms or bathrooms when the appliance is fitted, and any room with a working bath or shower. For rented homes, regulation 36(11) bars a fitting that would break 30(2) or (3) in a tenant's bedroom, unless the room was a bedroom before the 1998 Regulations came into force.

  • Worked example 1: a landlord wants a new combi in the cupboard of a back bedroom. A Logic Combi2 is room-sealed (C13, C33, C53), so regulation 30 allows it; the cupboard counts as the bedroom under 30(4), and the bedroom rule is met.
  • Worked example 2: a lounge with an open-flued 6 kW gas fire becomes a tenant's bedroom. The fire is 14 kW or less, so under 30(3) it may stay only if it has the safety control that shuts it down before fumes build up; without one, regulation 36(11) puts the landlord in breach.

Only a Gas Safe registered engineer can install, service or certify a gas appliance, and the decision on whether one is safe where it stands is theirs. This page sets out what regulation 30 and two makers' manuals say; the installation manual for the appliance in front of you is the one that applies.

On a Manifold gas safety check each appliance is recorded with its location and flue type, and the gas safety record the landlord receives lists every appliance by location with its flue result.

Frequently asked

Can you have a gas boiler in a bedroom?

Yes, if it is room-sealed. Regulation 30 bars an appliance over 14 kW gross from a bedroom unless it is room-sealed, and modern fanned-flue combis such as the Worcester Greenstar 4000 and Ideal Logic Combi2 are rated room-sealed types C13, C33 and C53.

Can a boiler go in a bedroom cupboard?

Yes, on the same terms as the bedroom. Regulation 30(4) treats a cupboard within the room, or next to it with an air vent into it, as part of the room, so a room-sealed boiler is allowed and an open-flued one over 14 kW is not.

Can you have a gas fire in a bedroom?

A room-sealed gas fire, yes. An open-flued fire of 14 kW gross or less is allowed only with a safety control that shuts it down before combustion products build up in the room. Above 14 kW only a room-sealed fire may go in a bedroom.

Can a combi boiler be installed in a bathroom?

Yes, if it is room-sealed, which regulation 30(1) requires of every gas appliance in a bathroom or shower room. The maker's electrical rating then decides the position: Ideal's Logic Combi2 must sit beyond Zone 2 under BS 7671, and Worcester rates the Greenstar 4000 IPX4D.

Does a landlord have to remove a gas fire if a room becomes a bedroom?

If the fire would breach regulation 30(2) or (3) in a bedroom, yes. Regulation 36(11) bars such a fitting in a room a tenant sleeps in, unless the room has been used or intended as a bedroom since before the 1998 Regulations came into force.

Is a 14 kW appliance allowed in a bedroom without being room-sealed?

Under regulation 30(3), an appliance of exactly 14 kW gross may go in a bedroom with a safety shut-down control. HSE's L56 guidance words the line as less than 14 kW, so the code and the regulation differ at exactly 14 kW; the regulation is the law.